TETRACHLOROETHYLENE Tube 135SA
1. PERFORMANCE
1) Measuring range :10-300 ppm 5-150 ppm 2.1-21 ppm
Number of pump strokes 1/2(50mL) 1(100mL) 2(200mL)
2) Sampling time :2 minutes/1 pump stroke
3) Detectable limit :1 ppm(100mL)
4) Shelf life :2 years(Necessary to store in regrigerated conditions ; 0 ~ 10℃)
5) Operating temperature :0~40℃
6) Temperature compensation:Necessary(See “TEMPERATURE CORRECTION TABLE”)
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Yellow→Red
Tetrachloroguaiacol
Product Code:DRE-C17358700
CAS Number:2539-17-5
Product Format:Neat
Lot Number:G1491475
Expiry:2030-08-22
Molecular Formula:C7 H4 Cl4 O2
Thermal Conductivity Analyzer
The Model 2020 & 2020 (ATEX) represents a complete line of Thermal Conductivity Detector (TCD) based analyzers which can be applied in a wide range of applications and industries. By using field proven filament-based and semiconductor based TC detectors, Teledyne is able to continuously monitor hydrogen and a variety of other gases of interest in either binary or multi-component sample gas streams
2020 – FM/CSA Approved when purchased with flame arrestors
2020 (ATEX) – ATEX/IECEx Approved, Flame arrestors included
Thermal Mass Flow Monitoring
The MDot™ is one of the most technically advanced gas flow meters specifically designed for water and wastewater. An innovative Thermal Mass Flow Meter and Temperature Transmitter that operates on the law that gases absorb heat. Specifically developed for the demands of the water and wastewater industry, where aeration, digestion, and cogeneration play crucial roles.
Thermocouples & Resistance thermometers
Another instrument used to measure temperature is the thermocouple. Our thermocouples are designed for a very wide range of applications and guarantee solid, accurate
and reliable temperature measurement between -200 °C and +1800 °C.
They are made by two different homogeneous metal conductors isolated throughout their
length. The two elements are joined at one end (hot end) and connected to a measuring
circuit at the other end (cold end).
The temperature difference between the hot and cold end creates a variable electromotive force in function of temperature and the conductors’ type.
Thermocouples model TR are copliant to different standards:
- UNI 7938
- ANSI MC96
- IEC 584
THERMODYNAMIC STEAM TRAPS
This type of trap uses steam dynamic energy to close the discharge orifice. A disc closes both the inlet and outlet orifice. Condensate can lift the disc and be discharge , but when steam is formed its dynamic energy will create a low pressure area ( Bernulli Law ) under the disc which draws it towards the seat.
THERMODYNAMIC STEAM TRAPS
This type of trap uses steam dynamic energy to close the discharge orifice. A disc closes both the inlet and outlet orifice. Condensate can lift the disc and be discharge , but when steam is formed its dynamic energy will create a low pressure area ( Bernulli Law ) under the disc which draws it towards the seat.
THERMODYNAMIC STEAM TRAPS
This type of trap uses steam dynamic energy to close the discharge orifice. A disc closes both the inlet and outlet orifice. Condensate can lift the disc and be discharge , but when steam is formed its dynamic energy will create a low pressure area ( Bernulli Law ) under the disc which draws it towards the seat.
THERMODYNAMIC STEAM TRAPS
This type of trap uses steam dynamic energy to close the discharge orifice. A disc closes both the inlet and outlet orifice. Condensate can lift the disc and be discharge , but when steam is formed its dynamic energy will create a low pressure area ( Bernulli Law ) under the disc which draws it towards the seat.
THERMODYNAMIC STEAM TRAPS
This type of trap uses steam dynamic energy to close the discharge orifice. A disc closes both the inlet and outlet orifice. Condensate can lift the disc and be discharge , but when steam is formed its dynamic energy will create a low pressure area ( Bernulli Law ) under the disc which draws it towards the seat.
THERMODYNAMIC STEAM TRAPS
This type of trap uses steam dynamic energy to close the discharge orifice. A disc closes both the inlet and outlet orifice. Condensate can lift the disc and be discharge , but when steam is formed its dynamic energy will create a low pressure area ( Bernulli Law ) under the disc which draws it towards the seat.
Thermohygrometer -50…+70°C 10-99% humidity, maximum/minimum function
This desk top thermohygrometer can be also used as wall hanged. The folding stand at the back housing offers a convenient angle for easy reading of the results. Water resistant sturdy plastic housing with 109 x 70 x 19 mm dimensions offers long life cycle. Offers dual display for humidity and temperature on a large and clear 40 x 30 mm LCD display. Featured with maximum & minimum temperature reading memory with an alarm function. Humidity measurement range is 10% RH – 99 %RH with +/- 1%RH accuracy. Temperature measurement range is -58°F to +158°F (+/- 0,2°F) or -50°C to +70°C (+/- 0,1°C) selectively. °F & °C values are exchangeable by a switch control at the front panel.
Through Conduit Expanding Gate Valves
BEL Valves’ Through Conduit Expanding Gate Valve enables double block and bleed (DBB) functionality to be achieved within one single valve assembly, as opposed to the two conventional slab gates that would otherwise be required.
Through Conduit Slab Gate Valves
BEL Valves’ reputation as a world-leading supplier has been built on the success of the Through Conduit Slab Gate Valve, a product first supplied in the mid-1980s. With thousands of installations throughout all oil and gas bearing regions in the world, the product is synonymous with high performance and reliability.
Thyristor power switch
Thyristor power switches are required for contactless switching of the alternating current loads. A typical application is the switching of ohmic-inductive loads at a high switching frequency, particularly in the industrial sector.
Tip Sensitive RTDs
Tip-sensitive, spring-loaded RTD temperature assemblies provide fast and accurate readings of bearings, blocks, frames and low pressure fluids. Minco’s spring loaded holder ensures solid contact in drilled holes and has a built-in oil seal
Tip Sensitive Thermocouples
Tip-sensitive, spring-loaded thermocouple temperature assemblies provide fast and accurate readings of bearings, blocks, frames and other surfaces. Minco’s spring loaded holder ensures solid contact in drilled holes and has a built-in oil seal.
TOC Sensor 4000e 110 VAC
Online TOC Sensor with Flow Control.The 4000TOCe online TOC sensor with flow control provides continuous, fast and reliable monitoring of TOC levels from reverse osmosis post-treatment to point-of-use.
TOC Sensor 6000i
Real-time Total Organic Carbon Control.The 6000TOCi online sensor delivers true continuous measurement for the detection of organic contamination. With an extremely rapid response to TOC changes, the 6000TOCi is ideal for all pure water applications where rapid detection of TOC changes is critical.
Tool for cone removal, for ELAN 9000/6×00/DRC
Interface Cones & Supplies for PerkinElmer ICP-MS Instruments
Tool for cone removal, for ELAN 9000/6×00/DRC. Compatible with Perkin Elmer ELAN 9000/6×00/DRC ICP-MS systems
Total Alkalinity Monitor
Measuring total alkalinity online can bring automation benefits over sporadic offline measurements, such as controlling cooling towers so they are operating in the ideal range for the Langelier Saturation Index, and ensuring that there is sufficient alkalinity for coagulation to take place during water treatment and ensuring that the alkalinity in pool water is optimised.
Total Alkalinity Test Strips, 0-240 mg/L, 50/pk
Caused by the presence of carbonates, bicarbonates, hydroxides, and other dissolved salts, alkalinity is important to drinking water, food, and beverage processors; boiler operators; and aquatic biologists. With Hach’s alkalinity test strips, technicians in the field can test many samples in only a few minutes, and make immediate evaluations on-site, without any measuring, set-up, clean-up, or chemical handling.
Total Hydrocarbon Analyzer
The Model 4020 Total Hydrocarbon Analyzer is a versatile instrument designed to measure the quantity of hydrocarbons present in a positive pressure sample as equivalent methane. The 4020 is a microprocessor controlled digital instrument based on Teledyne’s highly successful Model 402R series analog total hydrocarbon analyzer.
ToxiRAE Pro CO2
ToxiRAE Pro VOC Single Gas Monitor
Protect workers from the threat of volatile organic compounds (VOCs) in the workplace and observe conditions remotely from a central command station with this compact, wireless monitor. The ToxiRAE Pro PID’s next-generation sensor can detect over 300 VOCs and uses a built-in on-board library of 190 correction factors to automatically read gases in equivalent units. Reliable, rugged, and intrinsically safe, the ToxiRAE Pro PID can be easily attached to workers’ uniforms, and also provides a man-down alarm. It all adds up to better visibility and faster incident response in a variety of conditions.
TRA Series Absolute Gage Pressure Transducer
The Absolute Pressure Transducer utilizes CCS’ advanced strain Gage sensing and calibration technologies to measure pressure in aircraft systems referencing a fixed pressure adjusted to 0 PSI (0 BAR).
Transfer pumps KF
MODULAR STANDARD gear PUMP
In the standard version, the housing parts are made of cast iron. The gears are made of high-strength case-hardened steel, hardened and mounted in special multi-material plain bearing bushes. In the standard version, the drive shaft end is sealed by a rotary shaft seal. All sizes are made with helical gearing. This, in combination with a special gearing geometry, results in extremely low noise levels and low-pressure pulsation.
Transmitter
Transmitter M800 Process 1-CH
Convenience Meets Performance.The single-channel M800 Process is a multi-parameter transmitter that provides high-performance, reliable measurement with a convenient full-color touch screen and the ability to integrate with a wide range of ISM and analog sensors.
Intuitive Operation & Control
The M800 has a large, full-color touch screen interface and organized menu structure for easy operation with minimal training.
TraxOil oil management
Specifications
- Oil Level Management
- Refrigerants compatibilities
- HFC, HCFC and R744
- Application
- Compressors
- Medium
- Refrigerant and Oil
TRICHLOROETHYLENE Tube
1. PERFORMANCE
1) Measuring range :2.3-36.8 ppm 1-16 ppm 0.2-3.2 ppm
Number of pump strokes 1/2(50mr) 1(100mr) 4(400mr)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :0.1 ppm(400mr)
4) Shelf life :1 year(Necessary to store in refrigerated conditions ; 0~10℃)
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 1 pump stroke
7) Colour change :Pale orange→Blueish purple
Triple Adjustable Low Flow Tube Holder
Triple Multiple-tube Low Flow Holders holds 3 Tubes, protective tube covers sold separately; not for use with 222 Series Pumps
TS SERIES CENTRIFUGAL FANS/BLOWERS
Centrifugal fans type TS are designed for heavy duty industrial applications medium flow rate and where the complete reliability is considered essential.
Usual design conditions are:
- volumetric flowrate up to 250.000 m3/h
- static pressure up to 1400 mmH2O
- installed power up to 1000 kW
TU5200 Benchtop Laser Turbidimeter
The platform employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test. For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection® Technology in both, lab and process, instruments. The TU5 Series® dramatically reduces the time needed to get a turbidity measurement you can rely on.
Tubing and Retention Gaps
Undeactivated Fused Silica, 10 m, 0.05 mm, 0.36 mm OD
Tubing and Retention Gaps
Deactivated Fused Silica, High Temp, 5 m, 0.05 mm, 0.36 mm OD
Turbidity Meter
Online Turbidity Meters from Pi are called TurbSense® and include analysers, controllers and monitors which determine true online turbidity and/or suspended solids in water, using a nephelometric measurement of scattered light in accordance with ISO 7027. The TurbSense® sensor uses LED optical technology to provide an extremely stable, accurate, low maintenance sensor.
Turbidity Sensor
Turbidity Sensor InPro8610ie
Great Performance and Easy Handling.The InPro 8610i e turbidity sensor is designed for turbidity measurement in brewery, beverage, dairy or reclaimed water applications. It provides high measurement accuracy due to multipoint calibration and immunity to background changes.