نمایش 1–40 از 155 نتیجه
+Fixed Gas Detectors TXgard-IS
TXgard-IS+ is a Intrinsically Safe (I.S.) toxic and oxygen gas detector with local LCD display. A very wide choice of sensors are available for use in a variety of applications. The TXgard-IS+ toxic gas detectors are ATEX certified for use in Zone 0,1 or 2 hazardous areas and also UL and cUL certified for use in Division 1 or 2 hazardous areas.
191XL-CN Hazardous Location Zone Listed LED Light
- Available in 24VAC/DC and 120-240VAC
- Five lamp/lens colors: Amber, Blue, Clear, Green and Red
- Flashing mode standard, configurable to steady-burn
- 50,000 hour, vibration-resistant LED lamp
- Dome guard included
300GC SelecTone® Amplified Speaker
- Available in 24VAC/DC, 120VAC and 240VAC
- Built-in gain control, adjustable between 0 dBa to 110 dBa @ 10′ (0 dBa to 120 dBa @ 1m)
- Cast copper-free aluminum housing spun aluminum projector
- Digital signal amplification
- Fused input and output
310-MV AudioMaster® Two-Way Intercom
- Multi-voltage design accepts 24VDC and 120VAC/240VAC
- Heavy-duty industrial intercom for indoor or outdoor applications
- Balanced line output
- Call button
- Indoor/outdoor use
310-MV-MNC AudioMaster® Two-Way Intercom with Noise Canceling Microphone
- Multi-voltage design accepts 24VDC, 120VAC and 240VAC
- Heavy-duty industrial intercom
- Noise canceling microphone
- Call button
- Talk / Listen switch
- Volume control
- Auxiliary remote signal contact
31X and 41X Explosion-Proof Vibrating Horn
- 31X Available in 120VAC and 240VAC
- 41X Available in 24VDC
- Corrosion-resistant cast aluminum housings
- Produces 100 dBa @ 10′ (110 dBa @ 1m)
350 Vibratone® Horn
- Available in 12VAC, 24VAC, 120VAC and 240VAC
- Coded or sustained tones
- Produces 100 dBa @ 10′ (110 dBa @ 1m)
350 Vibratone® Horn
- Available in 12VAC, 24VAC, 120VAC and 240VAC
- Coded or sustained tones
- Produces 100 dBa @ 10′ (110 dBa @ 1m)
350WB Vibratone® Horn
- Available in 120VAC and 240VAC
- Coded or sustained tones
- Wall Mount
- Produces 100 dBa @ 10′ (110 dBa @ 1m)
350WBX Vibratone® Hazardous Location Horn
- Available in 120VAC and 240VAC
- Coded or sustained tones
- Produces 100 dBa @ 10′ (110 dBa @ 1m)
- Fuse terminal block provided for field wiring
450E Vibratone® Electronic Horn
- Fire Regulated 16-33VDC General Purpose Signal 12-24VDC
- Coded or sustained tones
- No duty cycle or interval limitations
- 99 dBa @ 10′ on axis (109 dBa @ 1m on axis)
- Four wire terminal block and supervisory diode
450EWBX Vibratone® Hazardous Location Electronic Horn
- No duty cycle
- Four wire terminal block and supervisory diode
- No detectable RF emissions in a 30-1000 MHz frequency range
- Type 4X enclosure
- IP69K compliant
- Marine Rated
605D Series Differential Switches
The 605D Series is a weather resistant, general purpose differential pressure switch. It is modeled after the 604 Series, designed specifically for high ingress and corrosion resistant applications. It has a modified face down side port electrical connection preventing any liquids from seeping into the inner workings of the switch. The 605D Series is easily mounted to bulkheads and ideal for extreme wet conditions, rated to NEMA 4X and IP66
611G Series Gage Switches
The 611G Series is an economical, compact sized, all aluminum gage pressure switch. It is modeled after our flagship 6900 Series with the same level of performance and quality but designed for applications where space and cost are a concern. It has high vibration and shock resistance utilizing Dual Snap® disc spring technology
6214GB Series Gage Switches
Utilizes highly reliable CCS Dual-Snap® Belleville disc spring technology.
Dual ports include debris clean-out port.
500°F rated O-Ring and Diaphragm.
Factory set to prevent incorrect adjustment of pressure settings.
Repeatable and stable set points.
Vibration and shock resistant.
High cycle life.
High System and Proof pressures for over-pressure capability.
Dual diaphragms including Teflon-Fiberglass.
Redundant micro switches to ensure safe operation.
Stainless Steel and Brass process connections available.
646GE Series Gage Switches
The hazardous locations 646GE Series is a rugged, heavy duty, all aluminum gage pressure switch. Similar to the 604 Series in design, the 646GE Series is rated to 15 Amps and UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified. It comes with high vibration and shock resistance utilizing Dual Snap® disc spring technology
646VE Series Vacuum Switches
The hazardous locations 646VE Series is a rugged, heavy duty, all aluminum vacuum pressure switch. Similar to the 604 Series in design, the 646VE Series is rated to 15 Amps and UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified. It comes with high vibration and shock resistance utilizing Dual Snap® disc spring technology
675DS Series Differential Switches
The 675DS Series is a low range, general purpose differential pressure switch designed with a large diaphragm, specifically for very low pressure settings (inches of water). The switch Series sets the market standard for meeting extremely low pressure applications, exceeding any other mechanically based sensor technology. It also has high vibration and shock resistance utilizing Dual Snap® disc spring technology
705 HT Series of Flammable Gas Sensors
The Model 705 high temperature sensor has been specifically designed for the detection of combustible gases in high temperature hazardous area locations. Typical applications include turbine enclosures and drying ovens used insolvent based printing and coating machines.
Absolute Gage Pressure Transducer
CCS’ highly reliable and economical Temperature Transducers utilize a Resistance Temperature Detector (RTD) for monitoring the temperature of aircraft fluids and gasses. The CCS Temperature Transducer is based on platinum wire-wound or thin-film RTD elements.pr
Accuro Pump Kit w/ Hard Sided Case
The Accuro Pump Kit with Hard Sided Case is a poisonous gas detector kit.
ACETONE Tube 102SA
1. PERFORMANCE
1) Measuring range :1.0-5.0% 0.1-2.0%
Number of pump strokes 1/2(50mr) 1(100mr)
2) Sampling time :1.5 minute/1 pump stroke
3) Detectable limit :0.02%(200 ppm)(100mr)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See “TEMPERATURE CORRECTION TABLE”)
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Orange→brown
ACETONE Tube 102SD
1. PERFORMANCE
1) Measuring range :125-5,000 ppm 50-2,000 ppm 20-800 ppm
Number of pump strokes 1/2(50mr) 1(100mr) 2(200mr)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :10 ppm(200mr)
4) Shelf life :2 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See “TEMPERATURE CORRECTION TABLE”)
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Yellow→Dark brown
ASHH and ASUH Hazardous Location Amplified Speakers
- 15 watt (ASHH) or 30 watt (ASUH)
- 24VDC
- Four wire supervisable power circuit
- Reliable, solid-state circuitry
- Digital signal amplification
- Fused input and output
- Built-in gain control
Autonomus combustible gas detector
S500L-IR and S500LT-IR models are high quality and autonomous NDIR (Non Dispersive Infra Red) gas sensors which offer a lot of sophisticated functions to give quick and reliable warnings against explosive concentrations of combustible gases.
Cable Harness CH1207
- For use with MSP Automotive Sensors
- 10 ft [3 m] Shielded Cable
- 2-Terminal
CCS Flow Switches
CCS Flow Switch design is based on differential pressure measurement across a venturi (Bernoulli effect) translated to flow rate. The Venturi measures a fluid’s flowrate by reducing the cross sectional flow area in the flow path and generating a pressure difference.
CO2, CO or CH4 Analyzer
The 2008-IR MP model is a compact and reliable instrument for specific measurement of CO2 or CO or CH4 in gas blending. The instrument is based on non dispersion Infra red method (NDIR).
CONDUCTIVITY CELL
Cells for measuring conductivity with plastic
body and platinum electrodes.
The cell constant is K = 1.0 cm, corresponding
to a measuring range of 0uS÷100 mS.
Supplied with integral PT 100 temperature
sensor for thermocompensation of the
measurement.
These cells are suitable for all normal industrial
and process uses.
They can be installed inside immersion probe
holders, flow cells or direct insertion into pipes.
Detection Tubes – Ethylene Oxide 1/a
These Expoxypropane short-term detection tubes have a measurement range of 1 to 15 ppm and come have a shelf life of 2 years. They come in a pack of 5 tubes and can also detect Ethylene Oxide , Oxirane and Propylene Oxide.
Detection Tubes – Formaldehyde 0.2/a
These Formaldehyde short-term gas detection tubes from Drager have a measurement range of 0.2 to 5 ppm (0.2/a). Other substances detected included
Acetaldehyde, Buten-2-al, n-Butyraldehyde, Crontonaldehyde, 1,3-Dioxolan, Formaldehyde, Furfural and Vinyl Acetate.
Detection Tubes – Hydrogen Sulphide + Sulphur Dioxide
Drager offer these short-term gas detection tubes for the measurement of Hydrogen Sulphide (H2S) + Sulphur Dioxide (SO2). The tubes come in a pack of 10 and have a measurement range of 0.2 to 7 vol%.
Detection Tubes – Hydrogen Sulphide 0.2%/a
These hydrogen sulphide (H2S) short-term gas detection tubes have a measurement range of 0.2 to 7 vol%.
Detection Tubes – Hydrogen Sulphide 0.5/a
Drager short-term gas detection tubes are known worldwide for their ability to carry out on-the-spot measurements of various gases. These particular tubes are Hydrogen Sulphide (H2S – 0.5a) and have a measurement range of 0.5 to 150 ppm.
Detection Tubes – Hydrogen Sulphide 1/c
The Drager Short Term Detection Tubes are ideal for the measurement of many different gases. This particular pack of tubes is for Hydrogen Sulphide (1/c) and they have a measurement range of 1-200ppm.
Detection Tubes – i-Propanol 50/a
Drager’s i-Propanol short-term gas detection tubes come in a pack of 10 and are used to detect levels of i-Propanol in the air.
These tubes can be used for on-spot measurements and must be used in conjunction with the Drager Accuro Gas Detection Pump. This manual bellows pump is also available to purchase on the Frontline Safety website.
DETECTOR TUBE, 1,1,1-TRICHLOROETHANE
DETECTOR TUBE, 1,1,1-TRICHLOROETHANE, 5/BX
(Twin Tube, 10 tubes = 5 tests)
DETECTOR TUBE, 1,1,1-TRICHLOROETHANE
DETECTOR TUBE, 1,1,1-TRICHLOROETHANE, 5/BX
(Twin Tube, 10 tubes = 5 tests)
DETECTOR TUBE, 1,2 DICHLOROETHANE
DETECTOR TUBE, 1,2 DICHLOROETHANE, 5/BX
(Twin Tube = 5 tests per box)
DETECTOR TUBE, 1,2-DICHLOROETHYLENE
DETECTOR TUBE, 1,2-DICHLOROETHYLENE, 10/BX
تجهیزات ایمنی آتش و گاز یکی از مهمترین بخشهای سیستمهای حفاظتی در صنایع نفت، گاز، پتروشیمی، پالایشگاه و سایر واحدهای صنعتی است. نوین پترو مجموعهای از تجهیزات تخصصی ایمنی، حفاظت فردی، تشخیص گاز، تشخیص شعله و سیستمهای Fire & Gas را برای کاربردهای مختلف صنعتی تأمین میکند.
این گروه شامل انواع دتکتور گاز ثابت و پرتابل، ترانسمیترهای تشخیص گاز، تجهیزات پایش گازهای قابل اشتعال و سمی، دتکتور شعله و تجهیزات مرتبط با سیستمهای Fire & Gas است. تجهیزات حفاظت فردی یا PPE نیز شامل محصولات مورد استفاده برای حفاظت تنفسی، سر، چشم، صورت و سایر نیازهای ایمنی محیطهای صنعتی میشود.
انتخاب تجهیزات ایمنی آتش و گاز باید متناسب با نوع خطر، شرایط محیطی، منطقه نصب، نوع گاز یا ماده قابل اشتعال و الزامات فنی پروژه انجام شود. نوین پترو تجهیزات تخصصی این حوزه را برای کاربردهای صنعتی و پروژههای نفت، گاز و پتروشیمی تأمین میکند.